Wednesday, September 23, 2015

Learn free Civil Engineering by Civilustaad about BASE SLAB REINFORCEMENT

http://civilustaad.blogspot.com/
BASE SLAB REINFORCEMENT

We go to all this effort to get the appropriate soil support system and what we end up with is a lone input value for the slab design. The most normally used value is the modulus of sub grade reaction, k. This value is not directly linked to bearing capacity and k does not tell the designer if there is compressible or expansive soil. What it does is specify how firm the sub-base / sub-grade is over small deflections (about 0.05 inches).


Now let's appear at why we need to recognize how flexible the sub-grade is. To start with it's vital to understand that a slab on ground is designed as "plain" concrete.


That way we do not count on the reinforcing steel to carry any of the loads. But hang around, you say, there's steel in the slab—mesh and re-bars. Yes, but that steel is merely there for crack control—to hold any cracks tightly together.


 It usually does not extend through the joints—at joints we only want to transfer shear forces, not bending moments and certainly not lateral restraint. That's what the joint is there for in the first position, to allow lateral shrinkage in the slab.

Sunday, September 20, 2015

Learn free Civil Engineering by Civilustaad about ANCHORING THE REINFORCEMENT OF THE UPPER FLOOR LEVEL

http://civilustaad.blogspot.com/

ANCHORING THE REINFORCEMENT OF THE UPPER FLOOR LEVEL


Column rebar must be properly anchored to the upper floor level in order to behave in the re-quire way.


The most effective way to anchor the upper floor column rebar is by creating a “concrete hat” on the summit of the column thus allowing the rebar to be anchored without being bent.



If the construction of a ‘column hat’ is not a enviable solution due to reasons like e.g. the need for a flat roof, then the column rebar of the upper floor can be anchored according to one of the following ways:


(a) Hooks bent at 180°

(b) Hooks bend at 90° (case A)


(c) Hooks bend at 90°(case B)



(d) Use of additional hairpin reinforcement bent at 90° or 180°


(e) When placing small bar diameters inside high-strength concrete mixtures, the straight an-chorage length might be short sufficient to fit within the joint area.